<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-28 19-04-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 41 dBuV SANDELS
Pilot RDS Phase Difference
5.9 kHz 4.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 68 kHz 5930 1,2648
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,48 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 13 kHz % above 76 kHz: 1,2648 Acquired: 2026/04/28 19.03.35 Total samples: 5930 Equivalent time: 0:04:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,6 dBr MIN: 3,9 dBr AVE: 5,48 dBr % above 12,2 dBr: 0,0 Last value: 5,7 dBr (2026/04/28 19.03.35) 18.50 18.52 18.54 18.56 18.58 19.00 19.02 0 2 4 6 Pm [dBr]